The flare is lit. Which valve is it?
US refineries are running harder than they have in years. When a unit upsets and the flare lights, most sites still can’t say which specific relief device released, when, or for how long.
Weekly US refinery utilization climbed to around 98% in late August 2026, the highest in eight years, after one of the lightest spring maintenance seasons in recent memory. Running at that rate leaves almost no slack. Equipment works closer to its limits, upsets become more likely, and every hour of unplanned downtime costs more.
When something does go wrong, the flare is often the first sign. It is also where the questions start: which of the dozens of relief devices tied into that header lifted? Did it reseat? Is anything still passing to flare now the unit is back up?
Without device-level monitoring, answering those questions can take hours, days or even weeks. That time is costly, and it is avoidable.
One flare, dozens of possible sources
A typical refinery flare header collects relief from many pressure relief devices (PRDs) across several process units. That design is sound: it routes releases safely to a control device instead of to atmosphere. But it also hides where each release came from.
The flare tells you that something released. Flare flow and composition monitoring can tell you how much went to the header. Neither tells you which device released.
So when the flare lights unexpectedly, or keeps burning after an upset has settled, the hunt begins:
- Operators walk the units, checking valves one at a time
- Technicians use handheld ultrasonic detectors or temperature guns on discharge lines
- Engineers piece together a timeline from DCS trends, pressure readings and shift logs
This takes hours or days, during a period when the site is already stretched. And the answer is often an informed guess rather than evidence.
What not knowing costs
Not knowing which device released has a price, even when the release itself was handled safely:
- Lost product. A relief valve that simmers or fails to reseat fully keeps sending hydrocarbon to flare or flare recovery. At high throughput, that is valuable product burned for nothing or recycled into fuel gas, often for weeks before anyone notices.
- Emissions and scrutiny. Every unexplained flaring hour adds to reported emissions and draws attention from regulators and neighbors.
- Slower restarts. Teams can’t confidently bring a unit back while a relief device might still be passing, so checks extend the outage.
- Weak root cause analysis. Without a record of which device opened and how it behaved, investigations rely on inference. Corrective actions may target the wrong equipment, and the same event can happen again.
- Inspection and maintenance spend. With little data on how each valve actually performs, many sites pull and test valves on fixed schedules, whether they need it or not.
Periodic checks can’t solve the problem
Relief events are brief and unpredictable. A valve can lift for seconds during an upset, chatter briefly, then reseat. Or it can reseat imperfectly and simmer quietly for months.
Periodic checks only see a valve at the moment someone is standing next to it. Handheld surveys and a bench test every few years are valuable, but they can’t tell you what happened at 03:00 last Tuesday. They also put people into hazardous or hard-to-reach locations to gather each data point.
Process instrumentation has a similar limit. Pressure and flow trends show that the system released, but rarely which device was responsible, especially when several share a header and it isn’t economical to hardwire a transmitter to every device.
To know what every relief device is doing, you need monitoring that is on the device and always listening.
From “the flare is lit” to “PSV-214 lifted at 03:12”
acoustoSENSE from Tribosonics is an always-on acoustic emissions monitoring system built for pressure relief devices. A small sensor clamps onto the valve body. It listens continuously in the 100–500 kHz range, where valve release events are clear and typical plant noise is filtered out, so alerts reflect real events rather than false positives – which has been tested successfully even under tornado conditions in Texas.
Every event is captured with its timing and waveform, so engineers can see how a valve behaved, not just whether it opened:
- Lift and reseat, with precise start time and duration
- Simmer, chatter, cycling and flutter, early signs of a valve with deteriorating condition or potential oversizing
- Continuous leakage, the slow losses that otherwise go unnoticed between inspections
When the flare lights, the dashboard shows which devices were active and when. After an upset, it confirms which valves have reseated before the unit restarts. And over months, it builds the performance history that lets sites move from fixed-interval testing to condition-based maintenance, aligned with API 576 RBI practices.
Built for refinery conditions:
- Non-intrusive: clamps on with no modification to the valve, so installation is quick
- Battery powered, with up to 10 years’ battery life and hot-swappable batteries
- Wireless LoRaWAN, site coverage achieved with only a few gateways
- ATEX/IECEx Zone 0, MET, CID1, CE, EMC certifications for hazardous areas
- Data in the Tribosonics cloud platform or completely on-premises, integrated into your own systems, with configurable real-time alerts
Proven in the field
One Gulf State offshore operator was spending $3,000–$10,000 per pop test across more than 1,000 PSVs, with that annual test as its only data point on each valve. With acoustoSENSE, it is targeting a 65% cut in PSV maintenance costs. Read the case study.
Know which valve, every time
Refineries will keep running hard. Upsets will happen. The question is whether your team spends the next one hunting for the source, or looking it up.
Talk to a valve monitoring specialist to see how acoustoSENSE would work on your flare header, or download the technical datasheet.